首页 | 本学科首页   官方微博 | 高级检索  
     检索      

变幅载荷下改善焊接接头疲劳性能的超声冲击与TIG熔修方法之比较
引用本文:王东坡,霍立兴,张玉凤,荆洪阳,杨新岐.变幅载荷下改善焊接接头疲劳性能的超声冲击与TIG熔修方法之比较[J].航空学报,2003,24(2):183-188.
作者姓名:王东坡  霍立兴  张玉凤  荆洪阳  杨新岐
作者单位:天津大学,材料科学与工程学院,焊接研究所,天津,300072
摘    要: 在恒幅和变幅两种加载条件下,对16Mn 钢原始焊态和经过超声冲击及TIG熔修处理的焊接接头进行了对比疲劳试验。结果表明: (1) 在恒幅载荷作用下,TIG熔修试件与焊态试件相比,疲劳强度提高37 %左右,疲劳寿命延长2.5 倍;而在变幅载荷作用下, TIG熔修试件与焊态试件相比,疲劳强度提高34 %左右,疲劳寿命延长1.7~1.9 倍。(2) 在恒幅载荷作用下,超声冲击处理试件与焊态试件相比,疲劳强度提高84 %左右,疲劳寿命延长3.5~27 倍;而在变幅载荷作用下,超声冲击处理试件与焊态试件相比,疲劳强度提高80 %左右,疲劳寿命延长2.5~17 倍。(3) 在低中应力水平、中长寿命区域内,无论是在恒幅载荷作用下还是在变幅载荷作用下,使用超声冲击法提高焊接接头疲劳强度较TIG熔修法的效果更好。

关 键 词:变幅载荷  超声冲击  TIG熔修  疲劳性能  
文章编号:1000-6893(2003)02-0183-06
修稿时间:2002年4月12日

Comparison of Ultrasonic Peening Method on Improving the Fatigue Behavior of Welded Joints with TIG Dressing under Variable-Amplitude Load
WANG Dong po,HUO Li xing,ZHANG Yu feng,JING Hong yang,YANG Xin qi.Comparison of Ultrasonic Peening Method on Improving the Fatigue Behavior of Welded Joints with TIG Dressing under Variable-Amplitude Load[J].Acta Aeronautica et Astronautica Sinica,2003,24(2):183-188.
Authors:WANG Dong po  HUO Li xing  ZHANG Yu feng  JING Hong yang  YANG Xin qi
Institution:Welding Graduate School; College of Material Science and Engineering; Tianjin University; Tianjin 300072; China
Abstract:Treated by ultrasonic peening or TIG dressing, the fatigue performance of welded joints and structures isto be improved significantly. This has been verified by many constant amplitude fatigue tests. Subjected to variableamplitude loads, the fatigue performance of the structures will be affected, so that the fatigue contrast tests of 16Mnsteel welded joints with fillet welds in three different conditions : TIG dressing, ultrasonic peening and as weldedcondition were performed. Test results indicated that : (1) Contrasted with the specimens in as welded condition thefatigue strength of the specimens treated by TIG-dressing is increased by about 37 % and the fatigue life is prolongedby 2.5 times when acted by constant amplitude load. When acted by variable amplitude load, contrasted with thespecimens in as welded condition the fatigue strength of the specimens treated by TIG dressing is increased by about34 % and the fatigue life is prolonged by 1.7~1.9 times. (2) When acted by constant amplitude load, contrastedwith the specimens in as welded condition the fatigue strength of the specimens treated by ultrasonic peening is increased by about 84 % and the fatigue life is prolonged by 3.5~27 times. But when acted by variable amplitudeload, contrasted with the specimen in as welded condition the fatigue strength of the specimens treated by ultrasonicpeening is increased by about 80 % and the fatigue life is prolonged by 2.5~17 times; (3) Whether acted by constant amplitude loads or by variable amplitude loads, in the low-medium stress level and medium-long life states theimprovement of fatigue strength of the welded joints created by ultrasonic peening is larger than that created by TIGdressing.
Keywords:variable amplitude load  ultrasonic peening  TIG dressing  fatigue performanc e
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《航空学报》浏览原始摘要信息
点击此处可从《航空学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号