Nondestructive testing of honeycomb structures by computerized,thermographic systems
Authors:R Monti  G Mannara
Institution:Institute of Aerodynamics “U. Nobile,” University of Naples, P. le V. Tecchio, 80 80125 Naples, Italy
Abstract:Complex honeycomb space structures (i.e. antennas, solar panels, etc.) must be inspected and accurately tested before flight.The thermography can be employed with success for the detection of the position of defects (delaminations, noneffective bondings, cracks, etc.) and for the evaluation of their size and geometry in all the cases in which the defect acts as a thermal resistance due to the low conductivity of the air filling the defect volume.The basic idea is to create in the specimen a heat flow distribution that is altered by the presence of the defect.The surface temperature distribution is then measured by means of a thermograph and is correlated with the presence of the defect.A numerical analysis and preliminary experiments have been carried out which show the feasibility of the method as applied to honeycomb structures.