首页 | 本学科首页   官方微博 | 高级检索  
     检索      


A comparison of quality factors and weighting factors for characterizing astronaut radiation exposures.
Authors:Neal Zapp  Frank Cucinotta  W Atwell
Institution:Wyle Laboratories, Houston, TX 77058, USA.
Abstract:Radiation exposures are typically characterized by two quantities. The first is the absorbed dose, or the energy deposited per unit mass for specific types of radiation passing through specified materials. The same amount of energy deposited in material by two different types of radiation, however, can result in two different levels of risk. Because of this, for the purpose of radiation protection operations, absorbed dose is modified by a second factor intended to normalize the risk associated with a given exposure. We present here an inter-comparison of methods for this modification. First is the radiation quality factor (Q), as defined by ICRP publication 60. This quantity is related functionally to the unrestricted linear energy transfer (LET) of a given radiation, and is multiplied by the absorbed dose to derive the dose equivalent (H). The second method for modifying absorbed dose is the radiation weighting factor, also given in ICRP-60, or as modified in NCRP report 115. To implement the weighting factor, the absorbed dose resulting from incidence of a particular radiation is multiplied by a factor assigned to that type of radiation, giving the equivalent dose. We compare calculations done based on identical fields of radiation representative of that encountered by the MIR space station, applying each of these two methods.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号