Negative body potential as result of modulated electron beam emission into ambient plasma
Authors:K Enninghorst  M M  nnighoff and M Roemer
Institution:

Space Research Center PAS, Bartycka 18A, 00-716, Warsaw, Poland

Abstract:Two different processes play an important role during emission of pulsed electron beam from a satellite: the positive charging of the spacecraft by emitted electron current and the body neutralization by ambient plasma electrons (mainly in pauses between electron pulses).

The injection of modulated electron beam (pulses of 2μs duration, E=8keV, I=0.1A and 25μs repetition) was carried on in the APEX Project. A simple computer model of this process for APEX scenario was performed.

The results show that after primary positive charging (during gun operation) a significant negative charging (in pauses between pulses) caused by neutralization process by ambient plasma with fp>2MHz takes place.