首页 | 本学科首页   官方微博 | 高级检索  
     检索      

热敏液晶测温标定及误差分析
引用本文:范玮,吕品.热敏液晶测温标定及误差分析[J].航空发动机,2009,35(1):50-52,6.
作者姓名:范玮  吕品
作者单位:北京航空航天大学,能源与动力工程学院,北京,100083
摘    要:对SPN/R30C20W型热敏液晶的特性进行了实验研究。实验以相机视角、光源强度、液晶厚度等参数作为对象,讨论了3种参数对液晶测温结果的影响。分析结果表明:在视角小于15°时,相机视角对液晶测温的影响可以忽略;光强不同导致由标定曲线计算出的最大温差达到5.5℃;液晶厚度对标定数据有较大的影响。该实验结论在液晶测温领域广泛应用。

关 键 词:液晶测温  液晶标定  误差分析

Calibration and Error Analysis of Temperature Measurement for Thermal Sensitive Liquid Crystal
Authors:FAN Wei  LV Pin
Institution:School of Jet Propulsion;Beijing University of Aeronautics and Astronautics;Beijing 100083;China
Abstract:The experimental investigation of characteristics of the thermal sensitive liquid crystal whose type is SPN/R30C20W was performed. The camera angle, light source intensity and liquid crystal thickness were regarded as parameters in the experiment and the effects of the three paran~eters on the liquid crystal temperature measurement were discussed. The analysis results show that: the effect of camera angle on the liquid crystal temperature measurement can be neglected when the angle is smaller than 15°; the maximal temperature difference calculated by the calibration curve can be as much as 5.5℃ due to the variety of light intensity; the liquid crystal thickness has remarkable influence on the calibration data, The experimental conclusions can be widely used in the field of liquid crystal temperature measurement.
Keywords:liquid crystal temperature measurement  liquid crystal calibration  error analysis  