首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
  国内免费   1篇
航空   2篇
航天技术   3篇
  2021年   1篇
  2019年   1篇
  2018年   1篇
  2010年   1篇
  2009年   1篇
排序方式: 共有5条查询结果,搜索用时 21 毫秒
1
1.
A systematic geometric model has been presented for calibration of a newly designed 5-axis turbine blade grinding machine. This machine is designed to serve a specific purpose to attain high accuracy and high efficiency grinding of turbine blades by eliminating the hand grinding process. Although its topology is RPPPR (P: prismatic; R: rotary), its design is quite distinct from the competitive machine tools. As error quantification is the only way to investigate, maintain and improve its accuracy, calibration is recommended for its performance assessment and acceptance testing. Systematic geometric error modeling technique is implemented and 52 position dependent and position independent errors are identified while considering the machine as five rigid bodies by eliminating the set-up errors of workpiece and cutting tool. 39 of them are found to have influential errors and are accommodated for finding the resultant effect between the cutting tool and the workpiece in workspace volume. Rigid body kinematics techniques and homogenous transformation matrices are used for error synthesis.  相似文献   
2.
In this research work, we have performed comparative diurnal variations of atmospheric Potential Gradient (PG) of fair-weather days by using the data of three stations installed in Northern, Pakistan for the year 2018. We investigated the impact of both local and global factors and meteorological parameters in the diurnal variation of atmospheric Potential Gradient on the annual and seasonal time scale. We observed two peaks, primary and secondary. This is because of the land-based measurements of annual and seasonal variations. The annual average curve of Potential Gradient of all three stations: Islamabad (CES), Muzaffarabad (MZF), and Balakot (BKT) demonstrated a notable deviation from the standard oceanic Carnegie curve. The atmospheric Potential Gradient variations are due to numerous meteorological factors e.g., air pollution, humidity, aerosol particles, fog, and temperature. Among three stations, the MZF station is located in highland (mountainous) and it demonstrated a higher atmospheric Potential Gradient. We further differentiate the results of our three stations with global results for authenticity and observed coherence between them. In addition, a positive correlation of fair-weather Potential Gradient is observed with temperature and a notable correlation between relative humidity and atmospheric Potential Gradient for all the three observatories.  相似文献   
3.
We report the results of ionospheric measurements from DPS-4 installed at Multan (Geog coord. 30.18°N, 71.48°E, dip 47.4°). The variations in F2-layer maximum electron density NmF2 and its peak height hmF2 are studied during the deep solar minimum between cycles 23 & 24 i.e 2008–2009 with comparisons conducted with the International Reference Ionosphere (IRI) versions 2012 & 2016. We find that the hmF2 observations peak around the pre-sunrise and sunrise hours depending on the month. Seasonally, the daytime variation of NmF2 is higher in the Equinox and Summer, while daytime hmF2 are slightly higher in the Equinox and Winter. High values of hmF2 around midnight are caused by an increase of upward drifts produced by meridional winds. The ionosphere over Multan, which lies at the verge of low and mid latitude, is affected by both E×B drifts and thermospheric winds as evident from mid-night peaks and near-sunrise dips in hmF2. The results of the comparison of the observed NmF2 and hmF2 for the year 2008–2009 with the IRI-2012 (both NmF2 and hmF2) and IRI-2016 (only hmF2) estimates indicate that for NmF2, IRI-2012 with Consultative Committee International Radio (CCIR) option produces values in better agreement with observed data. Whereas, for hmF2, IRI-2016 with both International Union of Radio Science (URSI) and CCIR SHU-2015 options, predicts well for nighttime hours throughout the year. However, the IRI-2012 with CCIR option produces better agreement with data during daytime hours. Furthermore, IRI-2012 with CCIR option gives better results during Equinox months, whereas, IRI-2016 with both URSI and CCIR SHU-2015 options predict well for Winter and Summer.  相似文献   
4.
Thrust chamber injector is very critical component since that small differences in its design can result in dramatically different performance. This paper presents a preliminary investigation of a mono-propellant jet–swirl nozzle for thrust chamber using the existing commercial nozzle made of brass with little modification. The performance of two types of spray pattern, i.e. hollow cone and solid cone were investigated under cold flow test. Two solid cone injectors were studied at various purely axial orifice diameter with all other parameters remaining constant. This investigation reveals that decrease in the breakup length increased the spray angle. Higher injection pressure leads to shorter breakup length and higher value of discharge coefficient, except for hollow cone nozzle which shows mild fluctuating trend. Experimental data also tells that solid cone nozzle with diameter ratio 0.14 has the highest average discharge coefficient (0.60), followed by hollow cone nozzle (0.25). Solid cone nozzle with diameter ratio of 0.1 has an average discharge coefficient of 0.21.  相似文献   
5.
In this study, Total Electron Content (TEC) observations acquired by a GNSS receiver installed at Sonmiani (Geog. Coord. 25.19°N, 66.74°E, Geomag. Coord. 17.62°N, 141.5°E) are being reported for the first time. The data utilized is hourly instantaneous TEC values during 10 International Quiet Days (IQDs) per month from Jul-14 to Jun-15, totaling 120 observation days for monitoring nominal TEC. The findings confirm the semi-annual trend of TEC over Sonmiani, which lies at the northern crest of Equatorial Ionization Anomaly (EIA) region. The TEC measurements are then compared with NeQuick-2 and International Reference Ionosphere (IRI-2012) models. It was found that the TEC values derived from NeQuick-2 are in better agreement with GNSS measurements than those from IRI-2012. The TEC measurements also show seasonal variation which is largest during Equinox months. The TEC value in Dec solstice is higher than the Jun solstice, which confirms that the seasonal anomaly is playing a major role in this region during the course of study.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号