首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
A new single-stage single-switch power factor correction converter with output electrical isolation is presented. The configuration of this converter is achieved by combining a flyback circuit and a forward circuit in one power stage. The principle of operation and steady-state analysis of the proposed topology is given. Based on its steady-state operation constraints, a design procedure along with a specific design example is reported. To verify the theoretical analysis of the proposed converter, a design example is given with its PSPICE simulation and experimental results  相似文献   

2.
The photovoltaic (PV) generator exhibits a nonlinear i-v characteristic and its maximum power (MP) point varies with solar insolation. In this paper, a V2-based MP point tracking (MPPT) scheme is developed using a buck-boost transformation topology. Although several buck-boost transformation topologies are available we have considered here a coupled inductor SEPIC converter for experimentation. To achieve almost ripple-free array current we have used ripple steering phenomena with the help of integrated inductor. This integrated inductor not only reduces the magnetic core requirements but also improves converter performance. Mathematical models are formulated and tracking algorithm is evolved. A combined PV system simulation model is developed in the SIMULINK. For a given solar insolation, the tracking algorithm changes the duty ratio of the converter such that the solar cell array (SCA) voltage equals the voltage corresponding to the MP point. This is done by the tracking algorithm, which mainly computes the power proportional to square of terminal voltage and changes the duty ratio of the converter so that this power is maximum. The proposed algorithm is implemented in real-time with the help of Analog Device ADMC-401 DSP evaluation module. The tracking program is developed to perform experimental investigations using analog-to-digital converter (ADC) interrupt. Using this processor we are able to track the MP within 200 ms. The proposed peak power tracking effectiveness is demonstrated through simulation and experimental results.  相似文献   

3.
为了提高三相四开关变换器并网电能质量,提出一种适用于不平衡电网条件的有限控制集模型预测直接功率控制策略。分析三相四开关变换器的工作机制和电压矢量变化关系,并建立其功率预测模型。使用αβ静止坐标系下的电网电压以及其90°延迟信号计算功率补偿值,设计价值函数,选择最优电压矢量对应的开关状态。该控制策略无需传统的正负序分离控制及锁相环技术,易于实现。仿真和试验结果表明,在不平衡电网条件下,所提出的控制策略能够有效降低并网电流畸变,消除功率波动,提高并网电能质量。  相似文献   

4.
Battery charger design for the Columbus MTFF power system   总被引:1,自引:0,他引:1  
A novel pulsewidth-modulated (PWM) dc-dc converter topology is proposed for the battery charge regulator (BCR) of the Columbus Man-Tended Free-Flyer (MTFF) power system. The system is a regulated bus system. Bus voltage control is implemented at the input of the BCR. The use of a conventional buck topology with PWM conductance control at the input results in a second-order behavior. A study of new PWM dc-dc converter topologies has been made to attain a suitable topology. The proposed converter topology is designed and a breadboard including the control loop has been built and tested. The experimental results show that the converter operates according to the design constraints.  相似文献   

5.
进行了模块化多电平变流器(Modular Multilevel Converter,MMC) 电路拓 扑结构分析,对其工作状态原理进行阐述。将MMC 电路拓扑应用到永磁直驱风力发电 系统,使用基于电容电压排序的矢量控制作为逆变器控制策略。通过仿真软件搭建所述 系统,仿真结果证实了控制方式的可行性。  相似文献   

6.
A novel high-frequency transformer linked full-bridge type soft-switching phase-shift pulsewidth modulated (PWM) controlled dc-dc power converter is presented, which can be used as a power conditioner for small-scale photovoltaic and fuel cell power generation systems as well as isolated boost dc-dc power converter for automotive ac power supply. In these applications with low-voltage large-current sources, the full-bridge circuit is the most attractive topology due to the possibility of using low-voltage high-performance metal-oxide-semiconductor field-effect transistor (MOSFET) and achieving high efficiency of the dc-dc power converter. A tapped-inductor filter including the freewheeling diode is newly implemented in the output stage of the full-bridge phase-shift PWM dc-dc converter to achieve soft-switching operation for the wide load variation range. Moreover, in the proposed converter circuit, the circulating current is effectively minimized without using additional resonant circuit and auxiliary power switching devices. The practical effectiveness of the proposed soft-switching dc-dc power converter was verified in laboratory level experiment with 1 kW 100 kHz breadboard setup using power MOSFETs. Actual efficiency of 94-97% was obtained for the wide duty cycle and load variation ranges.  相似文献   

7.
A fixed frequency LCL-type series resonant converter (SRC) which uses an inductive output filter is proposed. Steady-state analysis of the converter is presented using complex ac circuit analysis. Based on the analysis, a simple design procedure is given. Detailed space integrated control experiment (SPICE) simulation results are presented to evaluate the performance of the designed converter under varying load and supply voltage conditions. Also, detailed experimental results obtained from a metal-oxide-semiconductor field-effect transistor (MOSFET) based 500 W converter are presented to verify the analysis and SPICE simulation results. The results obtained from the analysis, SPICE simulation and the experimental converter are compared. The proposed converter requires a narrow variation in pulsewidth while maintaining lagging power factor mode of operation for a very wide variation in the load as well as supply voltage  相似文献   

8.
提出了一种新型的基于单周期控制的单位功率因数整流器为井下电机车供电。该电源由维也纳整流级和高频隔离DC-DC变换级两级功率变换器级联构成,但控制电路采用一级协调控制。电路控制简单,不需要乘法器和输入电压检测就可以实现单位功率因数运行,且可以降低开关器件一半的电压应力。详细分析了新型整流电路的基本工作原理和双闭环控制策略,并通过仿真和试验对此新型电路拓扑及其相应控制策略的正确性进行了验证。  相似文献   

9.
Photovoltaic (PV) generators exhibit nonlinear v-i characteristics and maximum power (MP) points that vary with solar insulation. An intermediate converter can therefore increase efficiency by matching the PV system to the load and by operating the solar cell arrays (SCAs) at their maximum power point. An MP point tracking algorithm is developed using only SCA voltage information thus leading to current sensorless tracking control. The inadequacy of a boost converter for array voltage based MP point control is experimentally verified and an improved converter system is proposed. The proposed converter system results in low ripple content, which improves the array performance and hence a lower value of capacitance is sufficient on the solar array side. Simplified mathematical expressions for a PV source are derived. A signal flow graph is employed for modeling the converter system. Current sensorless peak power tracking effectiveness is demonstrated through simulation results. Experimental results are presented to validate the proposed method  相似文献   

10.
A three-phase neutral point clamped (NPC) converter is presented for power factor correction and dc-link voltage regulation. A simplified space vector pulsewidth modulation scheme (SVPWM) is adopted to track line current commands. Using a simplified SVPWM algorithm, the calculated time for the time duration of voltage vector is reduced. The adopted NPC converter has less power switches compared with the conventional three-level NPC converter. Only eight power switches and four clamping diodes with voltage stress of half the dc bus voltage are used in the circuit configuration. Based on the proposed control algorithm, a reference voltage vector is generated on the ac terminal for drawing the sinusoidal line currents with unity power factor. Computer simulation and experimental results based on a laboratory prototype are presented to verify the validity and effectiveness of the proposed control strategy.  相似文献   

11.
A simple nonlinear discrete-time dynamic model for the series resonant dc-dc converter is derived using approximations appropriate to most power converters. This model is useful for the dynamic simulation of a series resonant converter using only a desktop calculator. The model is compared with a laboratory converter for a large transient event.  相似文献   

12.
A series-parallel resonant converter employing (LC)(LC)-type tank circuit operating in lagging power factor (PF) mode is presented and analyzed using complex ac circuit analysis. Design curves are obtained and the converter is optimized under certain constraints. Detailed Space Integrated Control Experiment (SPICE) simulation results are presented to evaluate the performance of the designed converter under varying load conditions. Results obtained from an experimental converter are also presented. The results obtained from the theory, SPICE simulation, and the experimental converter are compared. The proposed converter has high efficiency from full load to very light load (<10%). Switching frequency variation required for a wide change in the load (near load open circuit to full load) is narrow compared with the series resonant converter (SRC)  相似文献   

13.
A new ac/dc 3-/spl phi/ single-stage converter is proposed integrating a 3-/spl phi/ discontinuous current mode (DCM) boost with a dc/dc fixed frequency series resonant converter (SRC). This converter has the following features: natural power factor correction, soft switching, high-frequency (HF) transformer isolation with the series resonant tank operating in above resonance mode, etc. A new complementary gating control scheme is used for simultaneous control of boost converter and the SRC. Modes of operation are presented and analyzed. Based on the analysis, design curves are obtained. An optimum design is given and a design example is presented. Results obtained from SPICE simulation for the designed converter are given to verify the performance of the proposed converter for varying load as well as line voltage. Experimental results obtained from a laboratory prototype converter are presented to verify the theory.  相似文献   

14.
Switch-mode DC-to-AC inverters using DC-to-DC converter topology have many advantages over the traditional bridge-type inverter. A bidirectional power circuit combined with a nonlinear robust control is proposed to form a high performance inverter. The output voltage of the inverter can be stabilized regardless of large changes in input voltage and output current. The distortion near the zero crossing point can be minimized. The load of the inverter can be resistive, inductive, or capacitive. Simulation results and experimental verification are provided  相似文献   

15.
A representative switched-capacitor DC-DC converter topology is presented, circuit operation is explained, and control strategies are identified. State-space averaging is used to analyze steady-state performance and to develop control criteria and design equations. The analytical results are verified by SPICE simulation  相似文献   

16.
A 1 /spl phi/ high-frequency (HF) transformer isolated, soft-switching single-stage ac-dc converter with low line-current harmonic distortion is presented. Its operation is explained with equivalent circuits for the various intervals. The converter is analyzed and design curves are obtained. An optimization parameter is introduced and a systematic design procedure is illustrated with a design example. Detailed SPICE simulation and experimental results of a 500 W converter with load as well as line voltage variation are given to verify theory. The proposed converter employs a zero-voltage transition (ZVT) network to ensure zero-voltage switching (ZVS) at all loads, and natural power factor correction is ensured using a simple control circuit.  相似文献   

17.
详细介绍一种通过交直流变换共用主电路实现同一电源双路分时输出的方法,给出了交直流共用主电路的拓扑结构及其工作原理,分析了交流变换五电平载波移相及直流变换级联移相控制策略。为了在三相交流变换电路的基础上实现大功率直流输出,并兼顾各相功率均衡,提出了一种相位角同步的均流控制策略。最后通过试验实现了同一电源分时输出交流115 V/400 Hz/100 kVA和直流270 V/80 kW,验证了所述拓扑结构和控制策略的合理性与可行性。  相似文献   

18.
黄文新  胡育文 《航空学报》2002,23(4):377-380
 现代电力电子技术的发展使得笼型异步发电机能够适用于航空高压直流系统中。着重对笼型异步电机与电力电子变换器结合构成的发电系统进行了研究,说明了采用直接转矩控制策略可使这种发电系统具有很好的动态特性。介绍了异步发电机直接转矩控制的原理与实现方法,并给出了仿真与实验结果。  相似文献   

19.
Three pulse-width modulation (PWM) control schemes for a single-phase power-factor-correction (PFC) AC/DC converter are presented to improve the power quality. A diode bridge with two power switches is employed as a PFC circuit to achieve a high power factor and low line current harmonic distortion. The control schemes are based on look-up tables with hysteresis current controller (HCC) to generate two-level or three-level PWM on the DC side of diode rectifier. Based on the proposed three control schemes, the line current is driven to follow the sinusoidal current command which is in phase with the supply voltage, and two capacitor voltages on the DC bus are controlled to be balanced. The simulation and experimental results of a 1 kW converter with load as well as line voltage variation and shown to verify the proposed control schemes. It is shown that unity PFC is achieved using a simple control circuit and the measured line current harmonics satisfy the IEC 1000-3-2 requirements  相似文献   

20.
厉孟  谢桢  李长乐 《航空动力学报》2017,44(5):46-51, 79
传统交流组网风电场系统存在多次电能转换、成本高的问题。针对这个问题,设计了一种大容量直驱风电机组级联直流组网海上风电场系统,其直接将每台机组的直流输出级联形成高压直流进行传输,而无需额外的海上升压站平台。风电机组采用了永磁直驱风力发电机及其变流器,其中变流器包括了AC/DC单元和DC/DC单元,并设计了控制策略,即通过DC/DC单元的占空比调节来实现电流的持续输出和最大功率跟踪。陆基逆变电站采用晶闸管型逆变器,设计了工作模式和控制策略,其主要功能是实现高压直流链路的电压电流调节。最后,基于PSCAD/EMTDC仿真平台,搭建了容量为150 MW的风电场系统进行了仿真计算,计算结果验证了该系统具有较高的鲁棒性和对风速变化的适应性,同时每个机组都能独立的实现最大风能捕获。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号