共查询到11条相似文献,搜索用时 7 毫秒
1.
Jean-Jacques Valette Frank G. Lemoine Pascale Ferrage Philippe Yaya Zuheir Altamimi Pascal Willis Laurent Soudarin 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
For the first time, the International DORIS Service (IDS) has produced a technique level combination based on the contributions of seven analysis centers (ACs), including the European Space Operations Center (ESOC), Geodetic Observatory Pecny (GOP), Geoscience Australia (GAU), the NASA Goddard Space Flight Center (GSFC), the Institut Géographique National (IGN), the Institute of Astronomy, Russian Academy of Sciences (INASAN, named as INA), and CNES/CLS (named as LCA). The ACs used five different software packages to process the DORIS data from 1992 to 2008, including NAPEOS (ESA), Bernese (GOP), GEODYN (GAU, GSC), GIPSY/OASIS (INA), and GINS (LCA). The data from seven DORIS satellites, TOPEX/Poseidon, SPOT-2, SPOT-3, SPOT-4, SPOT-5, Envisat and Jason-1 were processed and all the analysis centers produced weekly SINEX files in either variance–covariance or normal equation format. The processing by the analysis centers used the latest GRACE-derived gravity models, forward modelling of atmospheric gravity, updates to the radiation pressure modelling to improve the DORIS geocenter solutions, denser parameterization of empirically determined drag coefficients to improve station and EOP solutions, especially near the solar maximum in 2001–2002, updated troposphere mapping functions, and an ITRF2005-derived station set for orbit determination, DPOD2005. The CATREF software was used to process the weekly AC solutions, and produce three iterations of an IDS global weekly combination. Between the development of the initial solution IDS-1, and the final solution, IDS-3, the ACs improved their analysis strategies and submitted updated solutions to eliminate troposphere-derived biases in the solution scale, to reduce drag-related degradations in station positioning, and to refine the estimation strategy to improve the combination geocenter solution. An analysis of the frequency content of the individual AC geocenter and scale solutions was used as the basis to define the scale and geocenter of the IDS-3 combination. The final IDS-3 combination has an internal position consistency (WRMS) that is 15 to 20 mm before 2002 and 8 to 10 mm after 2002, when 4 or 5 satellites contribute to the weekly solutions. The final IDS-3 combination includes solutions for 130 DORIS stations on 67 different sites of which 35 have occupations over 16 years (1993.0–2009.0). The EOPs from the IDS-3 combination were compared with the IERS 05 C04 time series and the RMS agreement was 0.24 mas and 0.35 mas for the X and Y components of polar motion. The comparison to ITRF2005 in station position shows an agreement of 6 to 8 mm RMS in horizontal and 10.3 mm in height. The RMS comparison to ITRF2005 in station velocity is at 1.8 mm/year on the East component, to 1.2 mm/year in North component and 1.6 mm/year in height. 相似文献
2.
Zuheir Altamimi Xavier Collilieux 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
Doppler Orbitography Radiopositionning Integrated by Satellite (DORIS) is one of the four fundamental techniques contributing to the ITRF. The optimal coverage over the globe of the DORIS observing sites and sites co-located with GPS, allow a strong embedding of DORIS within the ITRF network. DORIS contributes to the access to ITRF through precise orbit determination of altimetric satellites with onboard DORIS receivers. The DORIS contribution to the ITRF2008 is enhanced by the fact that the solutions of seven analysis centers were included in the submitted combined time series of weekly station positions and daily polar motion. We evaluate the quality of the DORIS combined solution in terms of its agreement with the other techniques (VLBI, SLR, GPS) contributing to the ITRF2008 combination. We show in particular that the precisions of the current IDS products range between 1.5 to 2.6 mm for station positions (at the epochs of minimum variances); better than 1 mm/yr in velocities and between 170 and 260 micro-arc-seconds for polar motion, a significant improvement by a factor of three to five, compared to past data used in the ITRF2005 combination. This improvement is certainly due to improved analysis strategies employed by the seven IDS analysis centers that contributed to the combined weekly submitted solutions of station positions and polar motion. A spectral analysis of DORIS station height time series indicates that annual and semi-annual signals are dominant. However, TOPEX draconitic period of about 118 days is still detected in about 20% of the station position power spectra. DORIS height annual signals correlate well with GPS annual signal estimated at some co-located stations, which show that DORIS technique is able to detect loading signals. 相似文献
3.
Pascal Willis Hervé Fagard Pascale Ferrage Frank G. Lemoine Carey E. Noll Ron Noomen Michiel Otten John C. Ries Markus Rothacher Laurent Soudarin Gilles Tavernier Jean-Jacques Valette 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
DORIS is one of the four space-geodetic techniques participating in the Global Geodetic Observing System (GGOS), particularly to maintain and disseminate the Terrestrial Reference Frame as determined by International Earth rotation and Reference frame Service (IERS). A few years ago, under the umbrella of the International Association of Geodesy, a DORIS International Service (IDS) was created in order to foster international cooperation and to provide new scientific products. This paper addresses the organizational aspects of the IDS and presents some recent DORIS scientific results. It is for the first time that, in preparation of the ITRF2008, seven Analysis Centers (AC’s) contributed to derive long-term time series of DORIS stations positions. These solutions were then combined into a homogeneous time series IDS-2 for which a precision of less than 10 mm was obtained. Orbit comparisons between the various AC’s showed an excellent agreement in the radial component, both for the SPOT satellites (e.g. 0.5–2.1 cm RMS for SPOT-2) and Envisat (0.9–2.1 cm RMS), using different software packages, models, corrections and analysis strategies. There is now a wide international participation within IDS that should lead to future improvements in DORIS analysis strategies and DORIS-derived geodetic products. 相似文献
4.
K. Le Bail F.G. Lemoine D.S. Chinn 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
The NASA GSFC DORIS analysis center has provided weekly DORIS solutions from November 1992 to January 2009 (839 SINEX files) of station positions and Earth Orientation Parameters for inclusion in the DORIS contribution to ITRF2008. The NASA GSFC GEODYN orbit determination software was used to process the orbits and produce the normal equations. The weekly SINEX gscwd10 submissions included DORIS data from Envisat, TOPEX/Poseidon, SPOT-2, SPOT-3, SPOT-4, SPOT-5. The orbits were mostly seven days in length (except for weeks with data gaps or maneuvers). The processing used the GRACE-derived EIGEN-GL04S1 gravity model, updated modeling for time-variable gravity, the GOT4.7 ocean tide model and tuned satellite-specific macromodels for SPOT-2, SPOT-3, SPOT-4, SPOT-5 and TOPEX/Poseidon. The University College London (UCL) radiation pressure model for Envisat improves nonconservative force modeling for this satellite, reducing the median residual empirical daily along-track accelerations from 3.75 × 10−9 m/s2 with the a priori macromodel to 0.99 × 10−9 m/s2 with the UCL model. For the SPOT and Envisat DORIS satellite orbits from 2003 to 2008, we obtain average RMS overlaps of 0.8–0.9 cm in the radial direction, 2.1–3.4 cm cross-track, and 1.7–2.3 cm along-track. The RMS orbit differences between Envisat DORIS-only and SLR & DORIS orbits are 1.1 cm radially, 6.4 cm along-track and 3.7 cm cross-track and are characterized by systematic along-track mean offsets due to the Envisat DORIS system time bias of ±5–10 μs. We obtain a good agreement between the geometrically-determined geocenter parameters and geocenter parameters determined dynamically from analysis of the degree one terms of the geopotential. The intrinsic RMS weekly position repeatability with respect to the IDS-3 combination ranges from 2.5 to 3.0 cm in 1993–1994 to 1.5 cm in 2007–2008. 相似文献
5.
6.
P. Willis J.C. Ries N.P. Zelensky L. Soudarin H. Fagard E.C. Pavlis F.G. Lemoine 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2009
For Precise Orbit Determination of altimetry missions, we have computed a data set of DORIS station coordinates defined for specific time intervals called DPOD2005. This terrestrial reference set is an extension of ITRF2005. However, it includes all new DORIS stations and is more reliable, as we disregard stations with large velocity formal errors as they could contaminate POD computations in the near future. About 1/4 of the station coordinates need to be defined as they do not appear in the original ITRF2005 realization. These results were verified with available DORIS and GPS results, as the integrity of DPOD2005 is almost as critical as its accuracy. Besides station coordinates and velocities, we also provide additional information such as periods for which DORIS data should be disregarded for specific DORIS stations, and epochs of coordinate and velocity discontinuities (related to either geophysical events, equipment problem or human intervention). The DPOD model was tested for orbit determination for TOPEX/Poseidon (T/P), Jason-1 and Jason-2. Test results show DPOD2005 offers improvement over the original ITRF2005, improvement that rapidly and significantly increases after 2005. Improvement is also significant for the early T/P cycles indicating improved station velocities in the DPOD2005 model and a more complete station set. Following 2005 the radial accuracy and centering of the ITRF2005-original orbits rapidly degrades due to station loss. 相似文献
7.
Marie-Line Gobinddass Pascal Willis Michel Menvielle Michel Diament 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
In preparation of ITRF2008, all geodetic technique services (VLBI, SLR, GPS and DORIS) are generating new solutions based on combination of individual analysis centers solutions. These data reprocessing are based on a selection of models, parameterization and estimation strategy unique to each analysis center and to each technique. While a good agreement can be found for models between groups, thanks to the existence of the IERS conventions, a great diversity still exist for parameter estimation, allowing possible future improvements in this direction. The goal of this study is to focus on the atmospheric drag estimation used to generate the new DORIS/IGN ignwd08 time series prepared for ITRF2008. We develop here a method to inter-compare different processing strategies. In a first step, by analyzing single-satellite solutions for a few weeks of data but for a large number of possible analysis strategies, we demonstrate that estimating drag coefficient more frequently (typically every 1–2 h instead of previously every 4–8 h) for the lowest DORIS satellites (SPOTs and Envisat) provides better geodetic results for station coordinates and polar motion. This new processing strategy also solved earlier problem found when processing DORIS data during intense geomagnetic events, such as geomagnetic storms. Differences between drag estimation strategies can mostly be found during these few specific periods of extreme geomagnetic activity (few days per year). In such a case, when drag coefficient is only estimated every 6 h or less often for single-satellite solution, a significant degradation in station coordinate accuracy can be observed (120 mm vs. 20 mm) and significant biases arose in polar motion estimation (5 mas vs. 0.3 mas). In a second step, we reprocessed a full year of DORIS data (2003) in a standard multi-satellite mode. We were able to provide statistics on a more reliable data set and to strengthen these conclusions. Our proposed DORIS analysis is easy to implement in all software packages and is now already used by several analysis centers of the International DORIS Service (IDS) when submitting reprocessed solutions for ITRF2008. 相似文献
8.
Xavier Collilieux Zuheir Altamimi David Coulot Tonie van Dam Jim Ray 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2010
The International Terrestrial Reference Frame (ITRF), as a realization of the International Terrestrial Reference System (ITRS), is represented by a set of station positions and linear velocities. They are intended to be used as regularized coordinates to which some corrections should be added to access instantaneous coordinates. The latest ITRS realization is the ITRF2005, which has integrated time series of station positions to form long-term solutions for the four space geodetic techniques. Currently, a purely linear model is used to parameterize station displacements in the estimation process, plus occasional discontinuities in case of earthquakes or equipment changes. However the input data have been derived without applying surface loading models and so surface loading effects are supposed to be embedded in the coordinates as measured quantities. We evaluate the effect of applying a posteriori loading corrections, which include the effect of atmospheric, non-tidal ocean, and continental water loading, to time series of positions estimated from Satellite Laser Ranging (SLR), Very Long Baseline Interferometry (VLBI), and Global Positioning System (GPS) data. We notice that they reduce about 50% or more of the annual signals in the translation and scale parameter time series of the SLR and VLBI techniques, except in SLR Z translation. In general, the estimated secular frame definition is negligibly affected and estimated positions and velocities are not significantly modified for stations that have accumulated a large number of observations. A multi-technique combination of such derived frames allows concluding that, for some cases, loading model corrections might degrade co-located station coordinates almost as much as they benefit them. However, most significant improvement of the estimated secular coordinates is observed for stations with less than 100 estimated positions as demonstrated with a multi-technique combination. 相似文献
9.
Guilhem Moreaux Pascal Willis Frank G. Lemoine Nikita P. Zelensky Alexandre Couhert Hanane Ait Lakbir Pascale Ferrage 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2019,63(1):118-138
To support precise orbit determination of the altimetry missions, the International DORIS Service (IDS) regularly estimates the DPOD (DORIS terrestrial reference frame for Precise Orbit Determination) solution which includes mean positions and velocities of all the DORIS stations. This solution is aligned to the current realization of the International Terrestrial Reference Frame (ITRF) and so, can be seen as a DORIS extension of the ITRF. In 2016, moving to the IDS Combination Center, the DPOD construction scheme changed. The new DPOD solution is produced from a DORIS cumulative position and velocity solution. We present the new methodology used to compute DPOD2014 and its validation procedure. In order to present geophysical applications and interpretations of these results, we show two examples: (1) the Gorkha earthquake (M7.8 – April 2015) generates a 3-D mis-positioning of nearly 55?mm of the EVEB DORIS station at the Everest base camp 90?km from the epicenter. (2) Applying the results the DPOD2014 realization, we show that the most recent vertical velocity of Thule, Greenland is similar to that observed between 2006 and 2010, indicating further ongoing ice mass loss in the Thule region of northwest Greenland. 相似文献
10.
星地无线电双向法时间比对计算模型及其误差评估 总被引:1,自引:0,他引:1
卫星导航定位系统测距的基础是测时,而定轨和定位的前提是各观测量的时间同步。因此,时间同步技术是卫星导航定位系统建设的关键技术基础之一。根据星地无线电双向法时间同步技术的基本原理,详细推导了其在地心惯性系中的基本计算模型,并以静止地球同步轨道卫星为例,分析了该计算模型中的距离改正项时延对星地间相对钟差的影响量级。 相似文献
11.
Siyao Wang Bofeng Li Xingxing Li Nan Zang 《Advances in Space Research (includes Cospar's Information Bulletin, Space Research Today)》2018,61(1):385-401
Integer ambiguity fixing with uncalibrated phase delay (UPD) products can significantly shorten the initialization time and improve the accuracy of precise point positioning (PPP). Since the tracking arcs of satellites and the behavior of atmospheric biases can be very different for the reference networks with different scales, the qualities of corresponding UPD products may be also various. The purpose of this paper is to comparatively investigate the influence of different scales of reference station networks on UPD estimation and user ambiguity resolution. Three reference station networks with global, wide-area and local scales are used to compute the UPD products and analyze their impact on the PPP-AR. The time-to-first-fix, the unfix rate and the incorrect fix rate of PPP-AR are analyzed. Moreover, in order to further shorten the convergence time for obtaining precise positioning, a modified partial ambiguity resolution (PAR) and corresponding validation strategy are presented. In this PAR method, the ambiguity subset is determined by removing the ambiguity one by one in the order of ascending elevations. Besides, for static positioning mode, a coordinate validation strategy is employed to enhance the reliability of the fixed coordinate. The experiment results show that UPD products computed by smaller station network are more accurate and lead to a better coordinate solution; the PAR method used in this paper can shorten the convergence time and the coordinate validation strategy can improve the availability of high precision positioning. 相似文献
