首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
We have measured charged nuclear fragments produced by 1 GeV/nucleon 56Fe ions interacting with aluminium, polyethylene and lead. These materials are relevant for assessment of radiation risk for manned space flight. The data will be presented in a form suitable for comparison with models of nuclear fragmentation and transport, including linear energy transfer (LET) spectrum, fluence for iron and fragments, event-tack- and event-dose-averaged LET, total dose and iron contribution to dose.  相似文献   

2.
This paper reports on DNA DSB induction in human fibroblasts by iron ions of different energies, namely 5, 1 GeV/u, 414 and 115 MeV/u, in absence or presence of different shields (PMMA, Al and Pb). Measure of DNA DSB was performed by calibrated Pulsed Field Gel Electrophoresis using the fragment counting method. The RBE-LET relationships for unshielded and shielded beams were obtained both in terms of dose average LET and of track average LET. Weak dependence on these parameters was observed for DSB induction. The shielding efficiency, evaluated by the ratio between the cross sections for unshielded and shielded beams, depends not only on the shield type and thickness, but also on the beam energy. Protection is only observed at high iron ions energy, especially at 5 GeV/u, where PMMA shield gives higher protection compared to Al or Pb shields of the same thickness expressed in g/cm2.  相似文献   

3.
Studies on the response of bacterial spores to accelerated heavy ions (HZE particles) help in understanding problems of space radiobiology and exobiology. Layers of spores of Bacillus subtilis strains, differing in repair capabilities, were irradiated with accelerated boron, carbon and neon ions of linear energy transfer (LET) values up to 14000 MeV cm2/g. Inactivation as measured by loss of colony forming ability and induction of mutations as measured by reversion to histidine prototrophy and resistance to 150 micrograms/ml sodium azide were tested, as well as the influence of repair processes on these effects. For inactivation, the cross-sectional values sigma plotted as a function of LET follow a saturation curve. The plateau, which is reached around a LET of 2000 MeV cm2/g, occurs at 2.5 x 10(-9) cm2, a value in good agreement with the dimensions of the spore protoplast. Lethal damage produced at LET values < 2000 MeV cm2/g is reparable. Recombination repair is more effective than excision repair. At higher LET values, lethal damage could not be reconstituted by the repair mechanisms studied. In addition, at these high LET values, the frequency of induced mutations was drastically decreased. The data support the assumption of at least two qualitatively different types of lesion, depending on the LET of the affecting heavy ion.  相似文献   

4.
The risk of radiation-induced cancer to space travelers outside the earth's magnetosphere will be of concern on missions to the Moon and beyond to Mars. High energy galactic cosmic rays with high charge (HZE particles) will penetrate the spacecraft and the bodies of the astronauts, sometimes fragmenting into nuclear secondary species of lower charge but always ionizing densely, thus causing cellular damage which may lead to malignant transformation. To quantitate this risk, the concept of dose equivalent (in which a quality factor Q as a function of LET is assumed) may not be adequate, since different particles of the same LET may have different efficiencies for tumor induction. Also, RBE values on which quality factors are based depend on response to low-LET radiation at low doses, a very difficult region for which to obtain reliable experimental data. Thus, we introduce a new concept, a fluence-related risk coefficient (F), which is the risk of a cancer per unit particle fluence and which we call the risk cross section. The total risk is the sum of the risk from each particle type: sigma i integral Fi(Li) phi i(Li) dLi, where Li is the LET and phi i(Li) is the fluence-LET spectrum of the ith particle type. As an example, tumor prevalence data in mice are used to estimate the probability of mouse Harderian gland tumor induction per year on an extra-magnetospheric mission inside an idealized shielding configuration of a spherical aluminum shell 1 g/cm2 thick. The combined shielding code BRYNTRN/GCR is used to generate the LET spectra at the center of the sphere. Results indicate a yearly prevalence at solar minimum conditions of 0.06, with 60% of this arising from charge components with Z between 10 and 28, and two-thirds of the contribution arising from LET components between 10 and 200 keV/micrometers.  相似文献   

5.
Among cosmic rays, the heavy nuclei ranging from carbon to iron provide the principal contribution to the dose equivalent. The LET-distributions and absorbed dose aid dose equivalent have been calculated and are presented as a function of shielding and tissue self-shielding. At solar minimum, outside the magnetosphere, the unshielded dose equivalent of nuclei with atomic number Z > or = 6 is about 47 rem/year. The contribution of the target nuclei adds 7 rem/year. With 4 g/cm2 aluminum shielding, and at a depth of 5 cm in a biological phantom of 30 cm diameter, the respective values are 11 and 10 rem/year. Corresponding dose rates for orbits with various inclinations are presented, as well as the LET distributions of various components of cosmic rays.  相似文献   

6.
We have flown two new charged particle detectors in five recent Shuttle flights. In this paper we report on the dose rate, equivalent dose rate, and radiation quality factor for trapped protons and cosmic radiation separately. A comparison of the integral linear energy transfer (LET) spectra with recent transport code calculations show significant disagreement. Using the calculated dose rate from the omni-directional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of (averaged over all geographic latitude) and longitude, we have determined the westward drift of the South Atlantic anomaly. We have also studied the east-west effect, and observed a 'second' radiation belt. A comparison of the galactic cosmic radiation lineal energy transfer spectra with model calculations shows disagreement comparable to those of the trapped protons.  相似文献   

7.
8.
Recent developments in NASA’s deterministic High charge (Z) and Energy TRaNsport (HZETRN) code have included lateral broadening of primary ion beams due to small-angle multiple Coulomb scattering, and coupling of the ion-nuclear scattering interactions with energy loss and straggling. This new version of HZETRN is based on Green function methods, called GRNTRN, and is suitable for modeling transport with both space environment and laboratory boundary conditions. Multiple scattering processes are a necessary extension to GRNTRN in order to accurately model ion beam experiments, to simulate the physical and biological-effective radiation dose, and to develop new methods and strategies for light-ion radiation therapy. In this paper we compare GRNTRN simulations of proton lateral broadening distributions with beam measurements taken at Loma Linda University Proton Therapy Facility. The simulated and measured lateral broadening distributions are compared for a 250 MeV proton beam on aluminum, polyethylene, polystyrene, bone substitute, iron, and lead target materials. The GRNTRN results are also compared to simulations from the Monte Carlo MCNPX code for the same projectile-target combinations described above.  相似文献   

9.
针对130 nm体硅反相器链,利用脉冲激光和重离子实验研究了目标电路单粒子瞬态(SET)的脉宽特性,并分析了电路被辐射诱发的SET脉宽特性受激光能量、重离子线性能量传递(LET)值、PMOS管栅长尺寸等因素的影响机制。重离子和脉冲激光实验结果类似,均表现为随激光能量、LET值的增加,电路被辐射诱发的SET脉宽逐步增大,且表现出明显的双(多)峰分布趋势,但辐射诱发的SET脉冲个数呈先增加再减少规律。此外,实验结果表明,在不同激光能量、LET值下,PMOS管栅长尺寸影响反相器链SET脉冲的特征不同。当激光能量、LET值较低时,PMOS管栅长尺寸大的电路产生的SET脉宽较大,而当激光能量、LET值较大时,PMOS管栅长尺寸小的电路反而产生更宽的SET脉冲。分析表明,较高激光能量、LET辐照时,寄生双极放大效应被触发可能是导致PMOS管栅长尺寸影响电路SET特征差异的主要原因。   相似文献   

10.
11.
The spatial distributions of ionization and energy deposition produced by high-velocity heavy ions are crucial to an understanding of their radiation quality as exhibited eg., in track segment experiments of cell survival and chromosome aberrations of mammalian cells. The stopping power (or LET) of a high velocity ion is proportional to the ratio z2/v2, apart from a slowly varying logarithmic factor. The maximum delta-ray energy that an ion can produce is proportional to v2 (non-relativistically). Therefore, two HZE ions having the same LET, but in general differing z and v will have different maximum delta-ray energies and consequently will produce different spatial patterns of energy deposition along their paths. To begin to explore the implications of this fact for the microscopic dosimetry of heavy ions, we have calculated radial distributions in energy imparted and ionization for iron and neon ions of approximately equal LET in order to make a direct comparison of their delta-ray track structure. Monte Carlo techniques are used for the charged particle radiation transport simulation.  相似文献   

12.
The aim of this research was to determine the biological effectiveness for early and delayed effects of high energy, high linear energy transfer (LET) charged particles. Survival and delayed reproductive death were measured in AG1522 human fibroblast cells exposed to Fe-ion beams of energies between 0.2 and 1 GeV/n, 0.97 GeV/n Ti-ion and 0.49 GeV/n Si-ion beams. The cells were irradiated at the HIMAC accelerator in Chiba, Japan (0.2 and 0.5 GeV/n Fe and 0.49 GeV/n Si) and at the NASA Space Radiation Laboratory in Brookhaven, USA (1 GeV/n Fe and 0.97 GeV/n Ti ions). The dose-effect curves were measured in the dose range between 0.25 and 2 Gy. For comparison cells were exposed to 60Co gamma rays. Analysis of the dose-effect curves show that all the heavy ion beams induce inactivation and delayed reproductive death more effectively than 60Co gamma rays. The only exception is the 0.2 GeV/n Fe-ion beam at low doses. The progeny of the irradiated cells show delayed damage in the form of reproductive death with all the heavy ion beams with the 1 GeV/n Fe-ion beam being the most effective. The relative biological effectiveness at low doses of the iron beams is highest for LET values between 140 and 200 keV/micrometers with values of 1.6 and 3 for early and delayed reproductive death, respectively. Analysis of the fluence-effect curves shows that the cross-sections for early and delayed inactivation increase with increasing LET up to 442 keV/micrometers.  相似文献   

13.
Cyclotron-accelerated heavy ion beams provide a fine degree of control over the physical parameters of radiation. Cytogenetics affords a view into the irradiated cell at the resolution of chromosomes. Combined they form a powerful means to probe the mechanisms of RBE. Cytogenetic studies with high energy heavy ion beams reveal three LET-dependent trends for 1) level of initial damage, 2) distribution of damage among cells, and 3) lesion severity. The number of initial breaks per unit dose increases from a low-LET plateau to a peak at approximately 180 keV/micrometer and declines thereafter. Overdispersion of breaks is significant above approximately 100 keV/micrometer. Lesion severity, indicated by the level of chromosomal fragments that have not restituted even after long repair times, increases with LET. Similar studies with very low energy 238Pu alpha particles (120 keV/micrometer) reveal higher levels of initial breakage per unit dose, fewer residual fragments and a higher level of misrepair when compared to high energy heavy ions at the same LET. These observations would suggest that track structure is an important factor in genetic damage in addition to LET.  相似文献   

14.
15.
The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 microGy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm-2 of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm-2 of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these detectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15-1000 keV/micrometer, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 microSv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members.  相似文献   

16.
Ion beam transport theory allows testing of material transmission properties in the laboratory environment generated by particle accelerators. This is a necessary step in materials development and evaluation for space use. The approximations used in solving the Boltzmann transport equation for the space setting are often not sufficient for laboratory work and those issues are the main emphasis of the present work. In consequence, an analytic solution of the linear Boltzmann equation is pursued in the form of a Green's function allowing flexibility in application to a broad range of boundary value problems. It has been established that simple solutions can be found for high charge and energy (HZE) ions by ignoring nuclear energy downshifts and dispersion. Such solutions were found to be supported by experimental evidence with HZE ion beams when multiple scattering was added. Lacking from the prior solutions were range and energy straggling and energy downshift with dispersion associated with nuclear events. Recently, we have found global solutions including these effects providing a broader class of HZE ion solutions.  相似文献   

17.
18.
The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.  相似文献   

19.
20.
基于0.13 μm部分耗尽绝缘体上硅(PD-SOI)工艺,设计了一款片上反相器链(DFF)单粒子瞬态(SET)脉宽测试电路并流片实现,SET脉宽测试范围为105~3 150 ps,精度为±52.5 ps。利用重离子加速器和脉冲激光模拟单粒子效应试验装置对器件进行了SET脉宽试验。采用线性能量传输(LET值)为37.6 MeV·cm2/mg的86Kr离子触发了反相器链的三级脉宽传播,利用脉冲激光正面测试器件触发了相同级数的脉宽,同时,激光能量值为5 500 pJ时触发了反相器链的双极放大效应,脉宽展宽32.4%。通过对比激光与重离子的试验结果,以及明确激光到达有源区的有效能量的影响因子,建立了激光有效能量与重离子LET值的对应关系,分析了两者对应关系偏差的原因。研究结果可为其他种类芯片单粒子效应试验建立激光有效能量与重离子LET值的对应关系提供参考。   相似文献   