首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Global Navigation Satellite System (GNSS) measurements of the Total Electron Content (TEC) from local (Dourbes, 50.1°N, 04.6°E) and European IGS (International GNSS Service) stations were used to obtain the TEC changes during the geomagnetic storms of the latest solar activity cycle. A common epoch analysis, with respect to geomagnetic storm intensity, season, and latitude, was performed on data representing nearly 300 storm events. In general, the storm-time behaviour of TEC shows clear positive and negative phases, relative to the non-storm (median) behaviour, with amplitudes that tend to increase during more intense storms. The most pronounced positive phase is observed during winter, while the strongest and yet shortest negative phase is detected during equinox. Average storm-time patterns in the TEC behaviour are deduced for potential use in ionosphere prediction services.  相似文献   

2.
This study presents the time variations of the total electron content in the South East Asian equatorial ionization anomaly. The time variation of the TEC is analyzed through the period 2006–2011 by using a latitudinal chain of GPS stations extending in the northern and southern hemisphere. The data shows that the shape of the diurnal variation of the TEC depends on the latitude: a plateau is observed at the stations near the equator and a Gaussian at the station distant from the equator. We observe a semiannual pattern in all the stations with maxima at equinox. In both hemispheres, the amplitude of the crest is larger in spring than autumn from 2006 to 2008 and smaller in spring than in autumn from 2009 to 2011. We also observe an asymmetry between the amplitude and the position of the two crests of ionization. There is a very high level of correlation between the amplitude of the TEC at the two crests and the sunspot number: ∼0.88. During the deep solar minimum 2008–2009, the amplitude of crests of ionization becomes small during several months in summer and winter. The results show that both crests move significantly equatorward in winter than other seasons and there is a tendency for both crests to appear earlier in winter and later in summer.  相似文献   

3.
The Earth's ionosphere and especially its equatorial part is a highly dynamical medium. Geostationary satellites are known to be a powerful tool for ionospheric studies. Recent developments in BDS-GEO satellites allow such studies on the new level due to the best noise pattern in TEC estimations, which corresponds to those of GPS/GLONASS systems. Here we used BDS-GEO satellites to demonstrate their capability for studying equatorial ionosphere variability on different time scales. Analyzing data from the equatorial SIN1 IGS station we present seasonal variations in geostationary slant TEC for the periods of high (October 2013 - October 2014) and low (January 2017 - January 2018) solar activity, which show semi-annual periodicity with amplitudes about 10 TECU during solar maximum and about 5 TECU during the solar minimum. The 27-day variations are also prominent in geostationary slant TEC variations, which correlates quite well with the variations in solar extreme UV radiation. We found semi-annual pattern in small scale ionospheric disturbances evaluated based on geostationary ROTI index: maximal values correspond to spring and fall equinoxes and minimum values correspond to summer and winter solstices. The seasonal asymmetry in ROTI values was observed: spring equinox values were almost twice as higher than fall equinox ones. We also present results on the 2017 May 28–29 G3 geomagnetic storm, when ~30 TECU positive anomaly was recorded, minor and final major sudden stratospheric warmings in February and March 2016, with positive daytime TEC anomalies up to 15–20 TECU, as well as the 2017 September 6 X9.3 solar flare with 2 TECU/min TEC rate. Our results show the large potential of geostationary TEC estimations with BDS-GEO signals for continuous monitoring of space weather effects in low-latitude and equatorial ionosphere.  相似文献   

4.
利用CHAMP卫星数据,对2002-2008年12个不同强度磁暴事件期间的热层大气密度变化特征进行分析,并研究对应磁暴期间大气模式NRLMSISE-00分布特征.结果表明,大磁暴期间日侧大气密度峰值从高纬到低纬的时间延迟为2h,中小磁暴期间的延迟时间为3~4h;春秋季暴时大气密度分布基本呈南北对称分布,而夏冬季大气密度的分布是夏半球大于冬半球,春秋季暴时大气密度大于夏冬季;NRLMSISE-00大气模式得到的热层大气密度很好的体现了半球分布以及季节分布的特征,但模式模拟结果偏小;Dst指数峰值比ap指数峰值更能反应大气密度的变化情况.   相似文献   

5.
The results of modeling of ionospheric disturbances observed in the East Asian region during moderate storms are presented. The numerical model for ionosphere–plasmasphere coupling developed at the ISTP SB RAS is used to interpret the data of observations at ionospheric stations located in the longitudinal sector of 90–130°E at latitudes from auroral zone to equator. There is obtained a reasonable agreement between measurements and modeling results for winter and equinox. In the summer ionosphere, at the background of high ionization by the solar EUV radiation in the quiet geomagnetic period the meridional thermospheric wind strongly impacts the electron concentration in the middle and auroral ionosphere. The consistent calculations of the thermospheric wind permit to obtain the model results which are closer to summer observations. The actual information about the space-time variations of thermosphere and magnetosphere parameters should be taken into account during storms.  相似文献   

6.
This paper presents an analysis of the Total Electron Content (TEC) derived from the International GNSS Service receiver (formerly IGS) at Malindi (2.9°S, 40.1°E), Kenya for the periods 2004–2006 during the declining phase of solar cycle 23. The diurnal, monthly and seasonal variations of the TEC are compared with TEC from the latest International Reference Ionosphere model (IRI-2007). The GPS–TEC exhibits features such as an equatorial noon time dip, semi-annual variations, Equatorial Ionization Anomaly and day-to-day variability. The lowest GPS–TEC values are observed near the June solstice and September equinox whereas largest values are observed near the March equinox and December solstice. The mean GPS–TEC values show a minimum at 03:00 UT and a peak value at about 10:00 UT. These results are compared with the TEC derived from IRI-2007 using the NeQuick option for the topside electron density (IRI–TEC). Seasonal mean hourly averages show that IRI-2007 model TEC values are too high for all the seasons. The high prediction primarily occur during daytime hours till around midnight hours local time for all the seasons, with the highest percentage deviation in TEC of more 90% seen in September equinox and lowest percentage deviation in TEC of less than 20% seen in March equinox. Unlike the GPS–TEC, the IRI–TEC does not respond to geomagnetic storms and does overestimate TEC during the recovery phase of the storm. While the modeled and observed data do correlate so well, we note that IRI-2007 model is strongly overestimating the equatorial ion fountain effect during the descending phase of solar cycle, and this could be the reason for the very high TEC estimations.  相似文献   

7.
本文论述过去十年中,在英国Aberystwyth城观测同步卫星Intelsat IIF2和SIRIO信标时获得的大西洋比斯开湾上空电子总量对磁暴的响应。所选择的地磁-电离层暴分属前后两个太阳活动较高周期,主要集中在春秋分阶段和冬夏至阶段。文中指出,春分期间连续型磁暴使TEC在正相效应之后出现加长的凋落周期,集中型磁暴导致TEC在正相之后产生凋落周期缩短;春秋分和冬夏至时磁暴伴生的电子总量形态受制于急始时刻与次数、磁暴主相、磁暴指数(即暴时位置和暴情指数)等因素。   相似文献   

8.
The Winter Anomaly (WA) is an ionospheric phenomenon, particularly related to the F2-layer, that is classically defined as the situation in which the ionization level during winter is higher than during summer for a certain location. This situation is anomalous because it contradicts what would be naturally expected with summer’s ionization levels higher than winter ones. This phenomenon has been a matter of study since the early decades of the XX century.This contribution tackles the study of the WA based on long time series (up to two solar cycles) of Total Electron Content (TEC) measurements over a globally distributed network of stations. The work done relies on a threefold strategy including: a classical approach based on the comparison of the winter and summer maximum TEC values, that confirmed the results previously documented; an intermediate approach with maximum TEC values modelled as linear functions of the solar radiation level, that allowed to identify stations where the WA is likely to be observed (and at what solar radiation level) and where is not; a final original approach where the maximum TEC values are modelled using Chapman’s function for the seasonal variations, linear regressions for the solar activity dependence and the introduction of site and month dependent equivalent ionization coefficients for the remaining effects. The main conclusions are that the coefficients for winter months seem to depend mainly on geomagnetic latitude, to increase towards high latitudes and to be asymmetric between hemisphere. In accordance to these findings, the occurrences of WA effects would be regulated by proper combinations of these three effects.  相似文献   

9.
利用全球分布的GPS原始观测数据提取的电离层总电子含量(TEC)分析了2004年11月6日至12日期间全球电离层暴的形态特点与发展过程.结果表明,11月8日磁暴主相期间电离层暴以大范围的强烈正暴为主,在11月10日的恢复相,Dst又一次降到最低值前后期间,电离层再次受到很强的扰动,大范围的正暴和负暴交替出现.这次磁暴期间夏季半球的负暴更加强烈,反映出负暴偏向于在夏季半球发生的季节变化特点.另外,磁暴期间,夜晚TEC值普遍比磁暴前的平静期要低,具体是什么机制导致还需要进一步收集数据和分析.   相似文献   

10.
This paper presents the vertical total electron content vTEC variations for three African stations, located at mid-low and equatorial latitudes, and operating since more than 10 years. The vTEC of the middle latitude GPS station in Alexandria, Egypt (31.2167°N; 29.9667°E, geographic) is compared to the vTEC of two others GPS stations: the first one in Rabat/Morocco (33.9981°N; 353.1457°E, geographic), and the second in Libreville/Gabon (0.3539°N; 9.6721°E, geographic). Our results discussed the diurnal, seasonal, and solar cycle dependences of vTEC at the local ionospheric conditions, during different phases of solar cycle in the light of the classification of Legrand and Simon. The vTEC over Alexandria exhibits the well-known equinoctial asymmetry which changes with the phases of the solar cycle; the spring vTEC is larger than that of autumn during the maximum, decreasing and minimum phases of solar cycle 23. During the increasing phase of solar cycle 24, it is the contrary. The diurnal variation of the vTEC presents multiple maxima during the equinox from 2005 to 2008 and during the summer solstice from 2006 to 2012. A nighttime vTEC enhancement and winter anomaly are also observed. During the deep solar minimum (2006–2009) the diurnal variation of the vTEC observed over Alexandria is similar to the diurnal variation observed during quiet magnetic period at equatorial latitudes. We observed also that the amplitude of vTEC at Libreville is larger than the amplitude of vTEC observed at Alexandria and Rabat, indeed Libreville is near the southern crest of the Equatorial Ionization anomaly. Finally, the correlation coefficient between vTEC and the sunspot number Rz is high and changes with solar cycle phases.  相似文献   

11.
电离层暴时经验模型STORM在中国区域的适应性研究   总被引:1,自引:1,他引:0       下载免费PDF全文
利用中国区域内9个垂测站1976---1987年一个太阳活动周期的电离层暴时f0F2数据, 统计分析了电离层暴事件的等级, 以及不同等级的电离层暴随季节和地磁纬度的分布特征. 研究发现, 中小型电离层暴在春秋季发生的概率较大, 不同季节的发生次数与地磁纬度具有明显的关系. 利用STORM模型对电离层暴时f0F2和大型及特大型电离层暴时f0F2的预测值与月中值进行了比较. 结果表明, 除了冬季误差增大外, 发生电离层暴时STORM模型能够有效地改善月中值模型. 增加中国的暴时数据, 并提高对冬季的暴时参数f0F2的预测是改善STORM模型的重要因素. 建立合适的暴时指数来预测f0F2是未来研究的重点.   相似文献   

12.
利用中国中低纬台站漠河(53.5°N,122.3°E)、北京(40.3°N,116.2°E)、武汉(30.5°N,114.2°E)和三亚(18.3°N,109.6°E)的电离层观测数据,对比分析了4个台站电离层参数在2015年不同季节4个地磁扰动事件期间的变化特征.结果表明,4个磁暴事件期间电离层的响应特征并不完全一致,有着明显的季节特征,春季、夏季和秋季电离层以负相扰动为主,冬季以正相扰动为主.分析发现,中性成分O/N2的降低与电离层负相扰动有关,但三亚地区的负相扰动还与扰动发电机电场相关.正相扰动的机制在不同事件中并不相同,穿透电场可能是引起春季磁暴事件期间电离层短时正暴效应的原因,而冬季长时间的正暴效应则是扰动电场和中性风共同作用的结果.   相似文献   

13.
This study presents a statistical analysis of GPS L-band scintillation with data observed from July 2008 to March 2012 at the northern crest of equatorial anomaly stations in Guangzhou and Shenzhen of South China. The variations of the scintillation with local time, season, solar activity and duration of scintillation patches were investigated. The relationship between the scintillation and TEC depletion was also reported. Our results revealed that GPS scintillation occurred from 19:30 LT (pre-midnight) to 03:00 LT (post-midnight). During quiet solar activity years, the scintillation was only observed in pre-midnight hours of equinox months and patches durations were mostly less than 60 min. During high solar activity years, more scintillation occurred in the pre-midnight hours of equinox and winter months; and GPS scintillation started to occur in the post-midnight hours of summer and winter. The duration of scintillation patches extended to 180 min in high solar activity years. Solar activity had a larger effect to strong scintillations (S4 > 0.6) than to weak scintillations (0.6 ? S4 > 0.2). Strong scintillations were accompanied by TEC depletion especially in equinox months. We also discussed the relationship between TEC depletion and plasma bubble.  相似文献   

14.
磁暴期间全球TEC扰动特性分析   总被引:3,自引:1,他引:2       下载免费PDF全文
磁暴期间白天电离层总电子含量(TEC)大幅度扰动.TEC扰动与磁暴发生时的世界时(UT)有关.利用7年的数据对TEC对磁暴的响应进行统计研究.结果显示,磁暴期间白天TEC增大明显,且在午后TEC的增大比例有一个高峰.在18:00UT-04:00UT,南美地区与其他地区相比TEC增长较大,这可能与白天的光照有关.为了研究TEC变化与磁暴的关系,结合同样时间段的Dst指数,把TEC数据分为磁暴日(Dst<-100nT)和平静日(Dst>-50nT).研究发现,将TEC前移2h,低纬日侧地区TEC增大值随着世界时的变化与Dst变化的负相关性较好,相关系数为-0.75.在中纬度地区,将TEC扰动前移1h,相关系数为-0.61.这可能是行进式大气扰动携带着赤道向的子午风,由极区向低纬传播引起.可以认为,TEC的变化可能是由磁暴引起的.在高纬地区,TEC增大值随着世界时的变化与Dst变化的相关性较差.这可能是由于太阳高度角较低,光辐射通量较小,导致电子密度的增加不明显.   相似文献   

15.
The solar cycle variation and seasonal changes significantly affects the ionization process of earth’s ionosphere and required to be monitored in real time basis for regional level refinement of existing models. In view of this, the present study has been carried out by using the ionospheric Total Electron Content (TEC) data observed with the help of Global Ionospheric Scintillation and TEC monitoring (GISTM) system installed at Indian Antarctic Research Station, “Maitri” [70°46′00″S 11°43′56″E] during the ascending phase of 24th solar cycle. The daily values of solar extreme ultraviolet (EUV) flux (0.1–50?nm wavelength), 10.7?cm radio flux F10.7 and Sunspot number (SSN) has been taken as a proxy to represent the solar cycle variation to correlate with TEC. The linear regression results revels better correlation of TEC with EUV flux rather than F10.7 and SSN. Also, the EUV and TEC show better agreement during summer as compared to winter and equinox period. Correlation between TEC and EUV appears significantly noticeable during ten internationally defined quiet days of each month (stable background geophysical condition) as compared to the overall days (2010–2014). Further, saturation effect has been observed on TEC values during the solar maxima year 2014. The saturation effects are more prominent during the night hours of winter and equinox season due to transportation losses manifested by the equator-ward direction of meridional wind.  相似文献   

16.
We used total electron content (TEC) data measured by Faraday rotation technique over Cachoeira Paulista (22.5°S, 45°W), in Brazil, to study the TEC variations with the solar flux at 10.7 cm (F10.7) and to compare the results with the IRI90 predictions. The data were divided into summer, equinox and winter. During the analysed period F10.7 varied from 66 up to 330. Our data shows that the observed TEC at 1600 LT (around the diurnal maximum) and at 0500 LT (around the diurnal minimum) increases with F10.7 until saturation is reached which occurs at F10.7≈210 to 220 for equinox and summer, and at F10.7≈180 for winter months. Comparison with the IRI90 predictions shows that IRI overestimates the TEC at 0500 LT for all solar flux values. At 1600 LT, IRI overestimates the observed TEC for low solar flux but underestimates it for high solar flux values.  相似文献   

17.
武汉地区电离层电子浓度总含量的统计经验模式研究   总被引:8,自引:4,他引:8  
由武汉电离层观象台一个太阳黑子周期(1980-1990年)的实测电离层电子浓度总含量(TEC)资料,统计分析得出了武汉地区的一个TEC经验模式,模式很好地再现了武汉地区的TEC观测值,其预测误差在太阳活动高年稍太,低年较小;在春秋两季稍大,冬夏两季较小;在当地时间白天和傍晚稍大,夜间和早晨较小。此外,与国际参考电离层模式IRI的计算结果比较,本模式预测的TEC值更接近于实际观测结果,同时,本文也初步探讨了TEC的半年变化特征和冬季异常现象。  相似文献   

18.
The temporal and seasonal variations of Total Electron Content (TEC) are studied at Agra (Geographic Lat. 27.17°N, Long. 78.89°E, Dip: 41.4°), India, which is in the equatorial anomaly region, for a period of 12 months from 01 January to 31 December, 2007 using a Global Positioning System (GPS) receiver. The mean TEC values show a minimum at 0500 h LT (LT = UT + 5.5 h) and a peak value at about 1400 h LT. The lowest TEC values are observed in winter whereas largest values are observed in equinox and summer. Anomalous variations are found during the period of magnetic disturbances. These results are compared with the TEC derived from IRI-2007 using three different options of topside electron density, NeQuick, IRI01-corr, and IRI-2001. A good agreement is found between the TEC obtained at Agra and those derived from IRI models.  相似文献   

19.
The total electron content (TEC) derived from GNSS measurements at a trans-hemispheric meridional chain of ground stations around 95°E longitude are used to study the quiet time inter-hemispheric structure and dynamics of the equatorial ionization anomaly (EIA) during the period March 2015 to February 2016. The stations are Dibrugarh (27.5°N, 95°E, 43° dip), Kohima (25.6°N, 94.1°E, 39° dip), Aizawl (23.7°N, 92.8°E, 36° dip), Port Blair (11.63°N, 92.71°E, 9° dip) and Cocos Islands (12.2°S, 96.8°E, 43° dip). The observation shows that the northern crest of the EIA lies in the south of 23°N (Aizawl) in all seasons but recedes further south towards the equator during December solstice. The largest poleward expansion of the northern (southern) EIA is observed in the March equinox (December solstice). The equinoctial and hemispherical asymmetry of TEC is noted. The winter anomaly is observed in the northern hemisphere but not in the southern hemisphere. The highest midday TEC over any station is observed in the March equinox. The TEC in southern summer (December solstice) is significantly higher than that in the northern summer (June solstice). The observed northern EIA contracts equatorward in the postsunset period of solstice but the southern EIA persists late into the midnight in the December solstice. The asymmetry may be attributed to the different geographic location of the magnetically conjugate stations. The SAMI3 simulations broadly capture the EIA structure and the inter-hemispheric asymmetry during solstices. The difference between observations and the SAMI3 is higher in March equinox and December solstice. The higher E?×?B vertical drift in the 90–100°E sector and the large geographic-geomagnetic offset in observing stations may have contributed to the observed differences.  相似文献   

20.
太阳活动低年低纬地区VTEC 变化特性分析   总被引:2,自引:0,他引:2  
利用福州台站(26.1°N, 119.3°E, 磁纬14.4°N)电离层闪烁与TEC监测仪2006-2010年的观测数据, 对该地区垂直总电子含量(VTEC)进行时间变化特性分析. 结果表明, 春秋冬三季的VTEC平均最高值出现在06:00UT, 夏季出现在08:00UT, 所有季节的平均最低值均出现在21:00UT; VTEC变化存在季节异常和弱冬季异常, 春秋季节高, 冬夏季节低, 夏季VTEC比冬季低且最大值出现时间延迟; VTEC在2006-2009年呈现下降的变化趋势, 2010年开始增强, 年际变化与太阳活动及地磁活动变化趋势具有较好的对应关系; VTEC变化与太阳活动存在很好的相关性, 相关系数达到0.5以上, 地磁活动则显示了弱相关的特性; F10.7与VTEC的相关性随着每天Kp指数总值Σkp的增大而减小.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号