首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
We assessed hemodynamic responses induced by orthostatic and mental stressors, using passive head up tilt (HUT) and mental arithmetic (MA), respectively. The 15 healthy males underwent three protocols: (1) HUT alone, (2) MA in supine position and (3) MA+HUT, with sessions randomized and ≥2 weeks apart. In relation to baseline, HUT increased heart rate (HR) (+20.4±7.1 bpm; p<0.001), mean blood pressure (MBP) (+4.7±11.3 mmHg; p<0.05), diastolic blood pressure (DBP) (+6.1±11.6 mmHg; p<0.05) and total peripheral resistance (TPR) (+155±232 dyne*s/cm5; p<0.001) but decreased stroke volume (SV) (?33.1±13.4 ml; p<0.001) and cardiac output (CO) (?0.6±1.0 l/min; p<0.01). MA increased HR (+8.0±6.0 bpm; p<0.001), systolic blood pressure (SBP) (+9.0±7.7 mmHg; p<0.001), MBP (+10.0±6.5 mmHg; p<0.001), DBP (+9.5±7.2 mmHg; p<0.001) and CO (+0.6±0.8 l/min; p<0.01). MA+HUT increased HR (+28.8±8.4 bpm; p<0.001), SBP (+4.6±14.3 mmHg; p<0.05), MBP (+11.2±11.6 mmHg; p<0.001), DBP (+13.5±10.1 mmHg; p<0.001) and TPR (+160±199 dyne*s/cm5; p<0.001) but SV (?34.5±14.6 ml; p<0.001) decreased. Mental challenge during orthostatic challenge elicited greater increases in heart rate, despite similar reductions in stroke volume such as those during orthostatic stress alone. Overall, cardiac output decreases were less with combinations of mental and orthostatic challenges in comparison to orthostasis alone. This would suggest that carefully chosen mental stressors might affect orthostatic responses of people on standing up. Therefore, additional mental loading could be a useful countermeasure to alleviate the orthostatic responses of persons, particularly in those with histories of dizziness on standing up or on return to earth from the spaceflight environment of microgravity.  相似文献   

2.
Introduction: This joint US–Russian work aims to establish a methodology for assessing cardiac function in microgravity in association with manipulation of central circulating volume. Russian Braslet-M (Braslet) occlusion cuffs were used to temporarily increase the volume of blood in the lower extremities, effectively reducing the volume in central circulation. The methodology was tested at the International Space Station (ISS) to assess the volume status of crewmembers by evaluating the responses to application and release of the cuffs, as well as to modified Valsalva and Mueller maneuvers. This case study examines the use of tissue Doppler (TD) of the right ventricular (RV) free wall. Results: Baseline TD of the RV free wall without Braslet showed early diastolic E′ (16 cm/s), late diastolic A′ (14 cm/s), and systolic S′ (12 cm/s) velocities comparable with those in normal subjects on Earth. Braslet application caused 50% decrease of E′ (8 cm/s), 45% increase of A′, and no change to S′. Approximately 8 beats after the Braslet release, TD showed E′ of 8 cm/s, A′ of 12 cm/s, and S′ of 13 cm/s. At this point after release, E′ did not recover to baseline values while l A′ and S′ did recover. The pre-systolic cross-sectional area of the internal jugular vein without Braslet was 1.07 cm2, and 1.13 cm2 10 min after the Braslet was applied. The respective cross-sectional areas of the femoral vein were 0.50 and 0.54 cm2. The RV myocardial performance Tei index was calculated by dividing the sum of the isovolumic contraction time and isovolumic relaxation time by the ejection time ((IVCT+IVRT)/ET); baseline and Braslet-on values for Tei index were 0.25 and 0.22, respectively. Braslet Tei indices are within normal ranges found in healthy terrestrial subjects and temporarily become greater than 0.4 during the dynamic Braslet release portion of the study. Conclusions: TD modality was successfully implemented in space flight for the first time. TD of RV revealed that the Braslet influenced cardiac preload and that fluid was sequestered in the lower extremity interstitial and vascular space after only 10 min of application. This report demonstrates that Braslet application has an effect on RV physiology in long-duration space flight based on TD, and that this effect is in part due to venous hemodynamics.  相似文献   

3.
《Acta Astronautica》2007,60(4-7):505-511
Effects of low-frequency electrical stimulation, which is currently considered to be a possible countermeasure for long-duration spaceflights, with and without stretch were evaluated. Twelve young male volunteers were randomly distributed into two groups. In one group anterior thigh muscles—knee extensors of both legs were stimulated with frequency of 15 Hz for 4.5 wks, six times a week; each session was 6-h long. In the other group, electrical stimulation with the same parameters was applied to stretched knee extensors. Following stimulation the subjects exhibited an increase in fatigue resistance, and in the succinate dehydrogenase activity and a 10% gain in the percentage of muscle fibers with slow myosin heavy chain isoforms. In a stimulated group the peak voluntary strength went down significantly, the CSA of fast muscle fibers in m. quadriceps femoris became slightly less in size (10%). Electrical stimulation of the stretched muscles induced an insignificant decline in their strength and an increase of cross-sectional area of muscle fibers of both types. Thus chronic low-frequency electrical stimulation may be proposed as a candidate countermeasure against muscle strength and mass loss if it is combined with stretch.  相似文献   

4.
5.
The mission complexity of Nanosatellites has increased tremendously in recent years, but their mission range is limited due to the lack of an active orbit control or ∆v capability. Pulsed Plasma Thrusters (PPT), featuring structural simplicity and very low power consumption are a prime candidate for such applications. However, the required miniaturization of standard PPTs and the adaption to the low power consumption is not straightforward. Most investigated systems have failed to show the required lifetime. The present coaxial design has shown a lifetime of up to 1 million discharges at discharge energies of 1.8 J in previous studies. The present paper focuses on performance characterizations of this design. For this purpose direct thrust measurements with a µN thrust balance were conducted. Thrust measurements in conjunction with mass bit determination allowed a comprehensive assessment. Based on those measurements the present µPPT has a total impulses capability of approximately I≈1.7 Ns, an average mass bit of 0.37 µg s−1 and an average specific impulse of Isp≈904 s. All tests have shown very good EM compatibility of the PPT with the electronics of the flight-like printed circuit board. Consequently, a complete µPPT unit can provide a ∆v change of 5.1 m/s or 2.6 m/s to a standard 1-unit or 2-unit CubeSat respectively.  相似文献   

6.
IntroductionLocomotor and some resistance exercises in space require a gravity replacement force in order to allow 1g-like ground reaction forces to be generated. Currently bungee cords, or other loading devices, interface with the crew member through a harness with a waist belt and shoulder straps. Crew members often find the application of the required loads to be uncomfortable, particularly at the hips.MethodsAn experimental harness was built that differed from previous in-flight designs by having a wider, moldable waist belt and contoured shoulder straps with additional padding. Eight subjects ran at 100% body weight (BW) loading for a total duration of 30 min per day on 12 days over a 3-week period in simulated 0-g conditions using horizontal suspension. A 100 mm Visual Analog Scale (VAS)1 was used to assess harness-related and lower extremity discomfort at the end of each run.ResultsThe overall rating of harness discomfort decreased from 27 mm on the 100 mm scale on day 1 to 10 mm on day 12, with significant decreases recorded for the back and hip regions as well as the overall harness.DiscussionThe experimental harness allows for repeated exposure to 30-minute bouts of 100% BW loaded simulated 0-g running with levels of discomfort less than 30 mm on a VAS scale of 0–100 mm. We believe that the use of such a harness during on-orbit exercise countermeasures may allow exercise to be performed at levels which are more effective in preventing bone and muscle loss.  相似文献   

7.
Nuclear Electric Propulsion (NEP) is a technology conceptually proposed since the 1940s by E. Stuhlinger in Germany. The JIMO mission originally planned by NASA in the early 2000s produced at least two designs of ion thrusters fed by a 20–30 kW nuclear powerplant. When compared to conventional (chemical) propulsion, the major advantage of NEP in the JIMO context was recognized to be the much higher Isp (lab-tested at up to 15,000 s) and the capability for sustained power generation, up to 8–10 years when derated to Isp about 8000 s.The goal of this paper is to show that current or near term NEP technology enables missions far beyond our immediate interplanetary backyard. In fact, by extending the semi-analytical approach used by Stuhlinger, with reasonable ratios α≡power/mass of the propulsion system (i.e., 0.1– 0.4 kW/kg), missions to the Kuiper Belt (40 AU and beyond) and even the so-called FOCAL mission (at 540 AU) become feasible with an attractive payload fraction and in times of order 10–15 years.Further results regarding missions to Sedna’s perihelion/aphelion, and to Oort’s cloud will also be presented, showing the constraints affecting their feasibility and mass budget.  相似文献   

8.
Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4±9.0 years, 69.5±15.4 kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. All training was conducted with the subject in orthostasis. When configured for spaceflight, subjects will be fixed to the device via a vest with loop attachments secured to subject load devices. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6 weeks, with additional improvements after 12 weeks (1.95±0.5, 2.28±0.5, 2.47±0.6 L min?1, and 131.2±63.9,182.8±75.0, 207.0±75.0 kg) for baseline, 6 weeks, and 12 weeks, respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3±39.5, 76.8±39.2, and 55.7±21.7 N m vs. 86.1±37.3, 85.1±34.3, and 62.1±26.4 N m, respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.  相似文献   

9.
The aim of this study was to characterize changes of serum proteome profile during 7-day “dry” immersion (DI). The experiment with DI consisted of three series: control group without countermeasures (10 men), with using mechanical stimulation (6 men) and low-frequency myostimulation (5 men) as preventive means. Serum samples were fractionated using ClinProt robot (Bruker Daltonics) on magnetic beads (weak cation exchange magnetic beads—MB WCX) prior to mass-spectral profiling. It was obtained 170 peaks after fractionation of serum samples in each group. On 7th immersion day peak areas of fibrinopeptide A (m/z=1206; 1464), angiotensin II (m/z=1051), high molecular mass kininogen fragment (m/z=2133 Da) and C3-fragment of the complement system (m/z=1350 Da) were significantly decreased comparing with pre-experimental values of all experimental series. Peak areas of apolipoprotein C III (m/z=9419) and C4a fragment of the complement system (m/z=3206 Da) were increased. On 7th day of the recovery peak areas of all changed peaks were not close to pre-experimental values. This fact provided evidence of incomplete recovery of an organism after DI. The depth of the alterations had considerable individual variability. Thereby the detected changes of serum proteome profile in the experiment. They indicated a reorganization of the hormonal, immune systems and lipid metabolism. The use of myostimulation and mechanical stimulation as countermeasures partly compensated adverse effects of 7-day dry immersion on the parameters of coagulation system (fibrinopeptide A) and lipid metabolism (apolipoprotein CIII).  相似文献   

10.
11.
More than 60 years after the late Nobel laureate Hannes Alfvén had published a letter stating that oscillating magnetic fields can accelerate ionised matter via magneto–hydrodynamic interactions in a wave like fashion, the technical implementation of Alfvén waves for propulsive purposes has been proposed, patented and examined for the first time by a group of inventors.Consequently improved since then, the name of the latest concept, relying on magneto-acoustic waves to accelerate electric conductive matter, is MOA2—Magnetic field Oscillating Amplified Accelerator. Based on computer simulations, which were undertaken to get a first estimate on the performance of the system, MOA2 is a corrosion free and highly flexible propulsion system, whose performance parameters might easily be adapted in operation, by changing the mass flow and/or the power level. As such the system is capable of delivering a maximum specific impulse of 13116 s (12.87 mN) at a power level of 11.16 kW, using Xe as propellant, but can also be attuned to provide a thrust of 236.5 mN (2411 s) at 6.15 kW of power. First tests—that are further described in this paper—have been conducted successfully with a 400 W prototype system at an ambient pressure of 0.20 Pa, delivered 9.24 mN of thrust at 1472 s ISP, thereby underlining the feasibility of the concept.Based on these results, space propulsion is expected to be a prime application for MOA2—a claim that is supported by numerous applications such as Solar and/or Nuclear Electric Propulsion or even as an ‘afterburner system’ for Nuclear Thermal Propulsion. However, MOA2 has so far seen most of its R&D impetus from terrestrial applications, like coating, semiconductor implantation and manufacturing as well as steel cutting. Based on this observation, MOA2 resembles an R&D paradigm buster, as it is the first space propulsion system, whose R&D is driven primarily by its terrestrial applications. Different terrestrial applications exist, but the most successful scenarios so far revolve around MOA2's unique features with respect to high throughput/low target temperature coatings on sensitive materials. In combination with its intrinsic high flexibility, MOA2 is highly suited for a common space-terrestrial application research and utilisation strategy.This paper presents the recent developments of the MOA2 R&D activities at Q2 Technologie(s), the company in Vienna, Austria, which has been set up to further develop and test the magneto-acoustic wave technology and its applications.  相似文献   

12.
The study of QT/RR relationship is important for the clinical evaluation of possible risk of acquired or congenital ventricular tachyarrhythmias. In the hypothesis that microgravity exposure could induce changes in the repolarization mechanisms, our aim was to test if a short 5-days strict 6° head-down bed-rest (HDBR) could induce alterations in the QT/RR relationship and spatial repolarization heterogeneity. Twenty-two healthy men (mean age 31±6) were enrolled as part of the European Space Agency HDBR studies. High fidelity (1000 Hz) 24 h Holter ECG (12-leads, Mortara Instrument) was acquired before (PRE), the last day of HDBR (HDT5), and four days after its conclusion (POST). The night period (23:00–06:30) was selected for analysis. X, Y, Z leads were derived and the vectorcardiogram computed. Selective beat averaging was used to obtain averages of P–QRS–T complexes preceded by the same RR (10 ms bin amplitude, in the range 900–1200 ms). For each averaged waveform (i.e., one for each bin), T-wave maximum amplitude (Tmax), T-wave area (Tarea), RTapex, RTend, ventricular gradient (VG) magnitude and spatial QRS-T angle were computed. Non-parametric Friedman test was applied. Compared to PRE, at HDT5 both RTapex and RTend resulted shortened (−4%), with a decrease in T-wave amplitude (−8%) and area (−13%). VG was diminished by 10%, and QRS-T angle increased by 14°. At POST, QT duration and area parameters, as well as QRS-T angle were restored while Tmax resulted larger than PRE (+5%) and VG was still decreased by 3%. Also, a marked loss in strength of the linear regression with RR was found at HDT5 in Tmax and Tarea, that could represent a new dynamic marker of increased risk for life-threatening arrhythmias. Despite the short-term HDBR, ventricular repolarization during the night period was affected. This should be taken into account in astronauts for risk assessment during space flight.  相似文献   

13.
Long-term sensitivity of human cells to reduced gravity has been supposed since the first Apollo missions and was demonstrated during several space missions in the past. However, little information is available on primary and rapid gravi-responsive elements in mammalian cells. In search of rapid-responsive molecular alterations in mammalian cells, short-term microgravity provided by parabolic flight maneuvers is an ideal way to elucidate such initial and primary effects. Modern biomedical research at the cellular and molecular level requires frequent repetition of experiments that are usually performed in sequences of experiments and analyses. Therefore, a research platform on Earth providing frequent, easy and repeated access to real microgravity for cell culture experiments is strongly desired. For this reason, we developed a research platform onboard the military fighter jet aircraft Northrop F-5E “Tiger II”. The experimental system consists of a programmable and automatically operated system composed of six individual experiment modules, placed in the front compartment, which work completely independent of the aircraft systems. Signal transduction pathways in cultured human cells can be investigated after the addition of an activator solution at the onset of microgravity and a fixative or lysis buffer after termination of microgravity. Before the beginning of a regular military training flight, a parabolic maneuver was executed. After a 1 g control phase, the parabolic maneuver starts at 13,000 ft and at Mach 0.99 airspeed, where a 22 s climb with an acceleration of 2.5g is initiated, following a free-fall ballistic Keplerian trajectory lasting 45 s with an apogee of 27,000 ft at Mach 0.4 airspeed. Temperature, pressure and acceleration are monitored constantly during the entire flight. Cells and activator solutions are kept at 37 °C during the entire experiment until the fixative has been added. The parabolic flight profile provides up to 45 s of microgravity at a quality of 0.05g in all axes. Access time is 30 min before take-off; retrieval time is 30 min after landing. We conclude that using military fighter jets for microgravity research is a valuable tool for frequent and repeated cell culture experiments and therefore for state-of-the art method of biomedical research.  相似文献   

14.
The scenarios for the long-term habitation of space platforms and planetary stations involve plants as fundamental part of Bioregenerative Life Support Systems (BLSS) to support the crew needs. Several constraints may limit plant growth in space: among them ionizing radiation is recognized to severely affect plant cell at morphological, physiological and biochemical level. In this work, plants of Phaseolus vulgaris L. were subjected to four different doses of X-rays (0.3, 10, 50 and 100 Gy) in order to assess the effects of ionizing radiation on this species and to analyze possible mechanisms carried out to overcome the radiation injuries. The effects of X-rays on plant growth were assessed by measuring stem elongation, number of internodes and leaf dry weight. The integrity of photosynthetic apparatus was evaluated by photosynthetic pigment composition and ribulose 1,5-bisphosphate carboxylase (Rubisco) activity, whereas changes in total antioxidant pool and glutathione S transferase activity (GST) were utilized as markers of oxidative stress. The distribution of phenolic compounds in leaf tissues as natural shielding against radiation was also determined.Irradiation of plants at 0.3 and 10 Gy did not determine differences in all considered parameters as compared to control. On the contrary, at 50 and 100 Gy a reduction of plant growth and a decrease in photosynthetic pigment content, as well as an increase in phenolic compounds and a decrease in total antioxidant content and GST activity were found. Only a slight reduction of Rubisco activity in leaves irradiated at 50 and 100 Gy was found. The overall results indicate P. vulgaris as a species with a good potential to face ionizing radiation and suggest its suitability for utilization in BLSSs.  相似文献   

15.
We explore the aftereffects of stand-off burst mitigation on kilometer-scale rubble pile asteroids. We use a simple model of X-ray energy deposition to calculate the impulse transferred to the target, in particular to burst-facing blocks on the target surface. The impulse allows us to estimate an initial velocity field for the blocks on the outer side of the target facing the burst. We model the dynamics using an N-body polyhedron program built on the Open Dynamics Engine, a “physics engine” that integrates the dynamical equations for objects of general shapes and includes collision detection, friction, and dissipation.We tested several different models for target objects: rubble piles with different mass distributions, a “brick-pile” made of closely fitting blocks and zero void space, and a non-spherical “contact binary” rubble pile. Objects were bound together by self-gravity and friction/inelastic restitution with no other cohesive forces. Our fiducial cases involved objects of m=3.5×1012 kg (corresponding to a radius of 0.7 km for the bulk object), an X-ray yield of 1 megaton, and stand-off burst distances of R=0.8–2.5 km from the target center of mass.Kilometer-scale rubble piles are robust to stand-off bursts of a yield (Y1 megaton) that would be sufficient to provide an effective velocity change (Δv0.05ms1). Disaggregation involving some tens of percent of the target mass happens immediately after the impulse; the bulk of the object re-accretes on a few gravitational timescales, and the final deflected target contains over 95% (typically, 98–99%) of the original mass. Off-center components of the mitigation impulse and the target mass distribution cause a small amount of induced spin and off-axis components of velocity change. The off-axis velocity component amounts to an angular deviation of 0.05–0.1 radians from the nominal impulse vector, which may be important for mitigation planning.  相似文献   

16.
Small satellites, weighting between 100 and 200 kg, have witnessed increasing use for a variety of space applications including remote sensing constellations and technology demonstrations. The energy storage/stored power demands of most spacecraft, including small satellites, are currently accommodated by rechargeable batteries—typically nickel–cadmium cells (specific energy of 50 Wh kg−1), or more recently lithium-ion cells (150 Wh kg−1). High energy density is a primary concern for spacecraft energy storage design, and these batteries have been sufficient for most applications. However, constraints on the allowable on-board battery size have limited peak power performance such that the maximum power supply capability of small satellites currently ranges between only 70 and 200 W. This relatively low maximum power limits the capabilities of small satellites in terms of payload design and selection. In order to enhance these satellites' power performance, the research reported in this paper focused on the implementation of super-capacitors as practical rechargeable energy storage medium, and as an alternative to chemical batteries. Compared to batteries, some super-capacitors are able to supply high power at high energy-efficiency, but unfortunately they still have a very low energy density (5–30 Wh kg−1). However, the provision of this high power capability would considerably widen the range of small satellite applications.  相似文献   

17.
In this paper we calculate the effect of atmospheric dust on the orbital elements of a satellite. Dust storms that originate in the Martian surface may evolve into global storms in the atmosphere that can last for months can affect low orbiter and lander missions. We model the dust as a velocity-square depended drag force acting on a satellite and we derive an appropriate disturbing function that accounts for the effect of dust on the orbit, using a Lagrangean formulation. A first-order perturbation solution of Lagrange's planetary equations of motion indicates that for a local dust storm cloud that has a possible density of 8.323×10−10 kg m−3 at an altitude of 100 km affects the orbital semimajor axis of a 1000 kg satellite up −0.142 m day−1. Regional dust storms of the same density may affect the semimajor axis up to of −0.418 m day−1. Other orbital elements are also affected but to a lesser extent.  相似文献   

18.
The history of the deployment of nuclear reactors in Earth orbits is reviewed with emphases on lessons learned and the operation and safety experiences. The former Soviet Union's “BUK” power systems, with SiGe thermoelectric conversion and fast neutron energy spectrum reactors, powered a total of 31 Radar Ocean Reconnaissance Satellites (RORSATs) from 1970 to 1988 in 260 km orbit. Two of the former Soviet Union's TOPAZ reactors, with in-core thermionic conversion and epithermal neutron energy spectrum, powered two Cosmos missions launched in 1987 in ~800 km orbit. The US’ SNAP-10A system, with SiGe energy conversion and a thermal neutron energy spectrum reactor, was launched in 1965 in 1300 km orbit. The three reactor systems used liquid NaK-78 coolant, stainless steel structure and highly enriched uranium fuel (90–96 wt%) and operated at a reactor exit temperature of 833–973 K. The BUK reactors used U-Mo fuel rods, TOPAZ used UO2 fuel rods and four ZrH moderator disks, and the SNAP-10A used moderated U-ZrH fuel rods. These low power space reactor systems were designed for short missions (~0.5 kWe and ~1 year for SNAP-10A, <3.0 kWe and <6 months for BUK, and ~5.5 kWe and up to 1 year for TOPAZ). The deactivated BUK reactors at the end of mission, which varied in duration from a few hours to ~4.5 months, were boosted into ~800 km storage orbit with a decay life of more than 600 year. The ejection of the last 16 BUK reactor fuel cores caused significant contamination of Earth orbits with NaK droplets that varied in sizes from a few microns to 5 cm. Power systems to enhance or enable future interplanetary exploration, in-situ resources utilization on Mars and the Moon, and civilian missions in 1000–3000 km orbits would generate significantly more power of 10's to 100's kWe for 5–10 years, or even longer. A number of design options to enhance the operation reliability and safety of these high power space reactor power systems are presented and discussed.  相似文献   

19.
《Acta Astronautica》2013,82(2):635-644
The Inner Formation Flying System (IFFS) consisting of an outer satellite and an inner satellite which is a solid sphere proof mass freely flying in the shield cavity can construct a pure gravity orbit to precisely measure the earth gravity field. The gravitational attraction on the inner satellite due to the outer satellite is a significant disturbance source to the pure gravity orbit and is required to be limited to 10−11 m s−2 order. However, the gravitational disturbance force was on 10−9 m s−2 order actually and must be reduced by dedicated compensation mass blocks. The region of relative motion of the inner satellite about its nominal position is within 1 cm in dimension, which raises the complexity of the compensation blocks design. The iterative design strategy of the compensation blocks based on reducing the gravitational attraction at the nominal position of the inner satellite is presented, aiming to guarantee the gravitational force in the relative motion region within requirements after the compensation. The compensation blocks are designed according to the current status of IFFS, and the gravitational disturbance force in the region is reduced to 10−11 ms−2 order with minimized adding mass.  相似文献   

20.
An analysis is performed on four typical materials (aluminum, liquid hydrogen, polyethylene, and water) to assess their impact on the length of time an astronaut can stay in deep space and not exceed a design basis radiation exposure of 150 mSv. A large number of heavy lift launches of pure shielding mass are needed to enable long duration, deep space missions to keep astronauts at or below the exposure value with shielding provided by the vehicle. Therefore, vehicle mass using the assumptions in the paper cannot be the sole shielding mechanism for long duration, deep space missions. As an example, to enable the Mars Design Reference Mission 5.0 with a 400 day transit to and from Mars, not including the 500 day stay on the surface, a minimum of 24 heavy lift launches of polyethylene at 89,375 lbm (40.54 tonnes) each are needed for the 1977 galactic cosmic ray environment. With the assumptions used in this paper, a single heavy lift launch of water or polyethylene can protect astronauts for a 130 day mission before exceeding the exposure value. Liquid hydrogen can only protect the astronauts for 160 days. Even a single launch of pure shielding material cannot protect an astronaut in deep space for more than 180 days using the assumptions adopted in the analysis. It is shown that liquid hydrogen is not the best shielding material for the same mass as polyethylene for missions that last longer than 225 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号