全光纤电流互感器λ/4波片的研制
惠菲,崔晶,左文龙,张书颖
0
(天津航海仪器研究所)
摘要:
光纤λ/4波片的相位延迟量与对轴角度误差是光纤电流互感器最主要的误差源之一。研究通过琼斯矩阵分析法建立反射式光纤电流互感器的偏振光学模型,进而得到了相位延迟量与对轴角度误差和标度因数之间的关系,为误差补偿技术提供理论支持。并且进行了实际研制,使得1/4波片消光比可小于0.2dB。
关键词:  
DOI:
基金项目:
Error Analysis of Quarter waveplate for Fiber Optical Current Transducer
HUI Fei,CUI Jing,ZUO Wen long,ZHANG Shu ying
(Tianjin Navigation Instrument Research Institute)
Abstract:
The phase delay and fusion alignment error of fiber optical quarter waveplate are the main reasons that makes the fiber optic current transducer(FOCT)instability.Based on the in line Sagnac interferometer setup,we analyzed and established the Jones matrix model of FOCT in this paper.The relationship between the phase delay and alignment error with the scale factor of FOCT was linked,which makes further error compensation available.And through experimental practice,the extinction ratio that is less than 0.2dB is developed.